The device is intended for non-drug therapy of a number of diseases in adults associated with impaired cerebral circulation, impaired autonomic regulation of cranial nerve trophism, electroencephalographic parameters, impaired homeostasis and adaptation, as well as with a decrease in the activity of the regulatory structures of the brain, in particular the hypothalamic-limbic system. In ophthalmology, the device is used to treat glaucoma (optic glaucoma neuropathy) and partial optic nerve atrophy.
the Transcranio apparatus is used:
In ophthalmology in glaucomatous neuropathy, partial atrophy of the optic nerve.
In cardiology for treatment of hypertension of I and II degrees, microcirculation disorders.
In otorhinolaryngology in treatment of sensorineural hearing loss, ear noise, vestibular disorders.
In psychiatry and narcology in depressive non-psychotic states, alcohol withdrawal syndrome and post withdrawal symptoms, affective disorders, borderline depressive states of moderate severity.
In urology in neuroendocrine disorders, for example, neurogenic urinary
In neurology, in cerebral disorders with lesions of the central nervous system in adults, including discirculatory encephalopathy (traumatic, toxic, post-inflammatory); cerebral spastic palsy; hyperkinesis; vertebrobasilar insufficiency syndrome; diencephalic syndrome; cognitive impairment; asthenic and autonomic disorders. Lesions of the peripheral nervous system, including vertebrogenic neurological syndromes caused by degenerative-dystrophic lesions of the spine and joints.
The main characteristics of the Transcranio apparatus
-Physiological effects of the magnetic field and IR laser radiation are coaxial and synchronized in the "running" mode
-Possibility of separate performance of magnetotherapy or laser therapy
-The device has indications for use both for treatment of adults and adolescents, and for treatment of infants and toddlers
Contents of delivery
Electronic unit of the device -1 pc.
Emitter of "running" magnetic field and IR-laser radiation "HEAD" - 1 pc.
Paired prismatic emitter of "traveling" magnetic field and IR laser radiation with removable tape clips - 1 pair
Magnetic field and IR laser sensor -1 pc.
Power cable -1 pc.
Technical characteristics of the Transcranio apparatus
The nature of the magnetic field is traveling
The number of magnetic field sources in one emitter is 6 pcs. (three in each emitter terminal)
The frequency of changing the magnetic field of each source (solenoid) in the emitter is 50 Hz; 80Hz and 100Hz selectable
Number of frequency ranges for switching magnetic field sources in the emitter
first range - 10-50Hz
second range - 10-80Hz
third range - 10-160Hz
Modes of magnetic field -"running",variable
"running" impulse positive
"running" impulse negative
The value of the induction of the "running" magnetic field on the working surface of the "Head" emitter and a paired prismatic emitter
in variable field mode:
in the switching frequency range 10-50Hz: 37 ± 3% mT
in the switching frequency range 10-80Hz: 24 ± 3% mT
in the switching frequency range 10-160Hz: 13 ± 3% mT
in pulsed positive and negative field mode:
in the switching frequency range 10-50Hz: 23 ± 3% mT
in the switching frequency range 10-80Hz: 18 ± 3% mT
in the switching frequency range 10-160Hz: 9 ± 3% mT