The AMO-ATOS-ICL device is intended for medication-free or local therapy of eye diseases accompanied by an edematous component, inflammation or disturbance of intraocular pressure and microcirculation in the structures of the visual analyzer and adjacent structures using a traveling (or stochastically switched) magnetic field and IR laser radiation.
Treatment principle
• Magnetotherapy
In ophthalmology, magnetotherapy is one of the most popular types of therapeutic effects and this is due to the high therapeutic properties of magnetic fields.
o High penetrating ability of the magnetic field, allows you to act on the deep structures of the organ of vision, without exerting thermal effects.
o The ability of a pulsed magnetic field to intensify transmembrane ion transport, which can significantly affect synaptic transmission, improving the conductivity of the nerve impulse.
o Vasodilating, anti-inflammatory, immunomodulatory, sedative and neurotropic effects of magnetic fields.
o A “running” pulsed magnetic field has the largest number of biotropic parameters and allows you to organize a dynamic and resonant effect with a field modulation frequency in the range of the main frequencies of the central nervous system (one of which is the organ of vision). This allows you to quickly form a response of the body and ensure high biological activity of the field.
o The vasodilating effect of the “traveling” pulsed magnetic field has a hypotensive effect, normalizes cerebrospinal fluid dynamics, and improves microcirculation.
• IR laser therapy
Laser radiation of the IR range has a wide range of therapeutic effects due to the greater penetration depth.
At the molecular level - it stimulates redox processes, increases the rate of synthesis of protein, enzymes.
At the cellular level - changes the membrane potential, increases proliferative activity, affects intracellular metabolism.
At the tissue level - it changes the pH of the intercellular fluid, increases microcirculation.
At the organ level, it normalizes the function of the organ (the result of reflex reactions), and also causes a generalized reaction of the body (activation of the endocrine glands and immune systems).
Distinctive features
Use of a "running" (or stochastically switched) magnetic field and infrared laser radiation in one coaxial emitter housing. The location of magnetic field sources and IR lasers along the optical axis of the eye.
Separate or joint, synchronous or asynchronous use of the magnetic field and infrared laser radiation.
The ability to use simultaneously two emitters of a magnetic field and infrared laser radiation.
Indications for use
• glaucoma;
• diabetic retinopathy;
• partial atrophy of the optic nerve;
• intraocular hemorrhages (hyphema, hemophthalmia, iridocyclitis, corneal imbibition);
• vascular eye diseases (blockages of the central retinal vein and its branches, peripheral chorioretinal dystrophies);
• keratitis, uveitis;
• any eye disease accompanied by swelling, inflammation;
• postoperative complications;
• amblyopia of any etiology;
• spasm of accommodation, prevention of myopia and its progression.
In addition, the device can be used in arthrology in the treatment of diseases such as arthrosis, arthritis, obliterating endarteritis and thromboangiitis, atherosclerotic lesions of the vessels of the extremities, as well as in dentistry, otorhinolaryngology and other areas of medicine. The methods are similar to those described for the apparatus
Specifications
Magnetotherapy block:
The number of traveling magnetic field sources (solenoids) in the emitter is 6 pcs.
The frequency of change of the magnetic field of each source (solenoid) in the emitter is 50 Hz
The frequency range of switching sources of magnetic field in the emitter 10-50 Hz
Arrangement of magnetic field sources (solenoids) in a circle around the optical axis of the eye
The number of switching modes of traveling magnetic field sources in the emitters is two: sequential;
stochastic
Modes of the magnetic field - three: variable;
pulse positive;
impulse negative
The magnitude of the induction of a traveling magnetic field on the working surface of the emitter in all three ranges of switching frequencies:
in variable field mode - 20 ± 2 mT
in pulsed positive and negative field mode - 10 ± 2 mT
Laser Therapy Unit:
The number of laser sources in the emitter 6 pcs.
The pulse repetition rate of 1500 Hz
The switching frequency range of laser sources 10-160 Hz
Laser spectrum - infrared (IR)
Type of laser - semiconductor
IR laser emission wavelength 0.85 ± 0.08 μm
The location of the laser sources inside the emitter in a circle around the optical axis of the eye between the sources of the magnetic field.
Timer block:
The procedure time set by the timer - from 1 to 15 minutes
Resolution of time- 1 min.
End of procedure - alarm intermittent beep
The operating mode of the device is repeated - short-term:
15min - work,
5min - pause
Establishment of the operating mode, no more than 10 s
The power consumed by the device from the network 220 ± 22 V 50 Hz, no more than 40V
Overall dimensions of the electronic unit 224 × 199 × 130mm
The mass of the electronic unit is 5.0 kg
The average service life of the device is at least 5 years
For safety, the device complies with GOST R 50267.0 and is made in terms of electrical safety as a class I type B product. For its operation, it is necessary to have a power outlet having a third contact connected to the ground loop (Euro socket).
According to the degree of danger of the generated laser radiation, the apparatus is made as a class II product.
Contents of delivery:
Electronic unit of the device "AMO-ATOS-ICL" - 1 pc.
Coaxial emitter of "traveling" magnetic field and infrared laser radiation - 1 pc.
Magnetic field sensor and infrared laser radiation - 1 pc.
Laser protective glasses- 2 pcs.
Power supply cable - 1 pc.
Operating Instructions - 1 pc.